Clamp Meters (AC)

F3000 (HT Instruments)

F3000 has been designed to measure AC current up to 3000A in TRMS in total autorange and reachs CAT IV 600V, CAT III 1000V according to standard IEC/EN61010-1.

The clamp is provided with innovative flexible current probe capable of reaching a maximum diameter of 110mm and allowing for an easy reading in any condition. The clamp is provided with a wide display with 3000 measuring spots, Data HOLD function and Backlight to allow for a simple reading even in poorly lit environments. The clamp is also provided with the auto power off function to preserve its own battery.

Current measuring range: 3000A

AC/DC current: AC

HT100 (HT Instruments)

Professional clamp meter HT100 is provided with automatic recognition of functions, or measuring AC current up to 200A and AC/DC voltage up to 1000V in TRMS to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/EN61010-1.

The clamp is provided of open jaws to measure current without breaking the circuit, with a wide display with 9999 measuring spots, Voltsense phase detector function, Data HOLD and backlight to allow for a simple reading even in poorly lit environments. HT100 also carries out measurements of Resistance, Continuity test and Diode test. The clamp is also provided with the auto power off function to preserve its own battery.

Current measuring range: 200A

AC/DC Current: AC

HT3010 (HT Instruments)

HT3010 current clamp can measure AC current up to 400A and AC/DC voltage up to 600V, resistance, continuity and diode test.

The instrument provides visual (LED) and audible (buzzer) indication of presence of AC voltage thanks to a non-contact internal detector. Complying with IEC / EN 61010-1, HT3010 is ideal for measurements in both domestic and industrial environments.

Measuring counts: 2000

Measuring counts: 600V

Measuring counts: 400A

HT4010 (HT Instruments)

Clamp meter HT4010 can carry out measurements of AC current up to 600A and AC/DC voltage, Resistance, Continuity and Diode test.

The device is provided with an internal sensor capable o detecting, through a LED turning on and a buzzer sounding, the presence of AC voltage in a spot without contact. This device complies with standard IEC/EN61010-1 in CAT III 600V and it is the ideal solution for measurements to be carried out both in private.

Current measuring range: 600A

AC/DC current: AC

AC/DC voltage: 600V

HT4011 (HT Instruments)

Clamp meter HT4011 has been designed to measure AC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/EN61010- 1.

The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. HT4011 also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

Current measuring range: 400A

AC/DC voltage: 600V

AC/DC current: AC

HT7004 (HT Instruments)

Clamp meter HT7004 is capable of measuring TRMS AC current up to 300A in Autorange, in compliance with IEC/EN61010-1, CAT III 300V. It is featured by Data HOLD, AC voltage measurement without contact, backlighting and auto power off to save internal battery. Thanks to its compact size it is suitable to effect simple measurements on both civil and industrial standard installations.

AC Current: 300A

HT9012 (HT Instruments)

Professional clamp meter HT9012 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Current measuring range: 600A

AC/DC current: AC

HT9014 (HT Instruments)

Demo

Professional clamp meter HT9014 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V TRMS to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Current measuring range: 600A

AC/DC current: AC

AC/DC voltage: 1000V

HT9019 (HT Instruments)

Professional clamp meter HT9019 has been designed to measure AC current up to 1000A and AC/DC voltage up to 1000V in TRMS to reach CAT IV 600V according to standard IEC/ EN61010-1.The clamp is provided with a wide display with 6000 measuring spots, backlight and analogue bargraph to allow for a simple reading even in poorly lit environments. Clamp HT9019 is also provided with the auto power off function to preserve its own battery.

Current measuring range:1000A

AC/DC current: AC

AC/DC voltage: 1000V

Clamp Meters (AC/DC)

ECLIPSE (HT Instruments)

ECLIPSE has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. ECLIPSE also measures Resistance, Frequency, Capacitance and Temperature with K-type probe and infrared temperature with built-in thermal camera. The Bluetooth connection allows for the transfer of the saved snapshots by means of the dedicated App HTMercury.

Current measuring range: 1000A

AC/DC current: AC+DC

AC/DC voltage: 1000VAC/1500VDC

Leakage current: External Clamp

HT3013 (HT Instruments)

HT3013 current clamp can measure AC/DC current up to 400A and AC/DC voltage up to 600V, resistance, frequency, capacitance, duty cycle, temperature by means of type K probes, continuity and diode test. The instrument provides visual (LED) and audible (buzzer) indication of presence of AC voltage thanks to a non-contact internal detector. Complying with IEC / EN 61010-1, HT3013 is ideal for measurements in both domestic and industrial environments.

Measuring counts: 6000

AC/DC voltage: 600V

AC/DC current: 400A

HT4013 (HT Instruments)

Clamp meter HT4013 has been designed to measure AC/ DC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/ EN61010-1.

The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. This model also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

AC/DC current: 400A

AC/DC voltage: 600V

HT7005 (HT Instruments)

Clamp meter HT7004 is capable of measuring TRMS AC current up to 300A in Autorange, in compliance with IEC/EN61010-1, CAT III 300V.

It is featured by Data HOLD, AC voltage measurement without contact, backlighting and auto power off to save internal battery. Thanks to its compact size it is suitable to effect simple measurements on both civil and industrial standard installations.

AC/DC current: 400A

Protection category: CAT III 300V

HT9015 (HT Instruments)

HT9015 has been designed to measure AC/DC current up to 600A and AC/DC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1.

The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9015 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.

HT9021 (HT Instruments)

HT9021 has been designed to measure AC/DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010- 1.

The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9021 also carries out measurements o voltage up to 1000V, Resistance, Frequency, Capacity and Temperature with K-type probe.

HT9025 (HT Instruments)

HT9025 has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9025 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.

HT9025T (HT Instruments)

HT9025T has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9025T also measures Resistance, Frequency, Capacitance and Temperature with K-type probe and infrared temperature with built-in thermal camera 120 x 120 pxl. The Bluetooth connection allows for the transfer of the saved snapshots by means of the dedicated App HTMercury.

Clamp Meters (Leakage)

HT77C (HT Instruments)

New model HT77C is clamp meters designed for an accurate measurement of very low values of AC currents and, therefore, they are mainly employed in detecting and and defining leakage currents in private and industrial electric systems, which typically cause RCDs’ tripping. Clamp meters are provided, among others, with an integrated lowpass filter to eliminate harmonic components.

HT79 (HT Instruments)

The HT79 clamp is designed primarily for the measurement of AC and DC leakage currents and measurement of currents up to 10A (DC) and 20A (AC) in reaching CAT IV 300V according to IEC / EN61010-1. Other measures envisaged are the AC / DC Voltage, Resistance and Continuity Test measurement. The instrument has a 5000-point display, display backlight, auto-off function to preserve its internal battery. HT79 can clamp a conductor with a maximum size of 23mm. Other important functions present are the MIN / MAX for the detection of the Maximum and Minimum value of the quantities, the Data HOLD function and the ZERO function for the execution of preliminary zeroing of the currents.

LINESPLITTER (HT Instruments)

LINESPLITTER was designed by HT to carry out splitting among active Phase, Neutral and PE conductors on single-phase installations powered by 2- or 3-pole cord cables up to 16A absorption. You will be able to take immediate measurements of current by means of clamps/DMMs which would be otherwise impossible without stripping the cable to get access to individual conductors. This unit is is powered by 230V mains supply through built-in shuko plug. LINESPLITTER complies with IEC/EN61010-1 standards for electronic equipment. It can be used for CURRENT and AC VOLTAGE measurements on CAT II 240V earthed installations with max load current of 16A.

Clamp Meters (Power and Harmonics)

HT4020 (HT Instruments)

HT4020 carry out measurements in TRMS of AC current up to 400A, AC/DC voltage up to 600V, Frequency, Resistance, Continuity test, Active, Reactive, Apparent Power, Cos , Energy for balanced single-phase and/or three-phase systems, further to the detection of phase sequence by 1-terminal method. Each device complies with IEC/EN61010-1 in CAT III 600V and is the ideal solution or troubleshooting typical problems in industrial environments such as non-linear loads, frequency-controlled motors.

AC/DC current: AC

AC/DC voltage: 600V

Current measuring range: 400A

HT4022 (HT Instruments)

HT4022 carry out measurements in TRMS of AC current up to 400A, AC/DC voltage up to 600V, Frequency, Resistance, Continuity test, Active, Reactive, Apparent Power, Cos , Energy for balanced single-phase and/or three-phase systems, further to the detection of phase sequence by 1-terminal method.

Model HT4022 also carries out the absolute/percentage measurement of voltage and current harmonic components with calculation of THD%. Each device complies with IEC/EN61010-1 in CAT III 600V and is the ideal solution or troubleshooting typical problems in industrial environments such as non-linear loads, frequencycontrolled motors.

HT9023 (HT Instruments)

DemHT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems. It is also possible to carry out the phase sequence test with 1-terminal. The instrument also detects the events linked to motor starting currents (Dynamic INRUSH) and allows recording each measured electric parameter over time, with the possibility of transferring data via WiFi to Android/iOS devices through the HTAnalysis App (available from late 2020) or onto PC through the TOPVIEW software. The clamp is provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments, and it is provided with an auto power off function to preserve its internal battery.o

HT9020 (HT Instruments)

HT9020 carries out measurements of Active, Reactive and Apparent Power and Energy, voltage and current harmonic analysis up to the 25th order with THD% calculation, in single-phase or three-phase balanced systems. It also tests phase sequence and phase conformity by 1-lead measuring method as well as detects any event related to electric motor starting currents (DYNAMIC INRUSH). DYNAMIC INRUSH™ permits to measure inrush currents with user-defined time frames, providing measurements more reliable than standard fixed time-frame testers. The user has the chance to recall and display the measurement by applying different time frames. For example, if the user carries out a measurement using a time frame of 100 ms, he can post-process the same measurement by applying a time frame of: 16,7, 20, 50, 100, 150, or 200 ms. This grants the utmost flexibility for each measurement, and prevents to measure again and again to get the real inrush current value. HT9020 is provided with traceable calibration certificate.

Clamp-on power quality analyzer HT9020 has been designed for measuring DC, AC+DC TRMS current up to 1000A according to CAT IV 600V in compliance with standard IEC/EN61010-1

Current measuring range: 1000A

AC/DC voltage: 1000V

AC/DC current: AC+DC