HT2055 consists in a power unit and a voltmetric unit, necessary for carrying out step and
contact voltage measurements in industrial electric installations (TN systems, transformer
cabinets) with a rated test current up to 50A.
The two units, synchronized in time and current are capable of providing the correct
value of step and contact voltages consistently with the real current values measured by the
power unit, also taking into consideration the disturbance effects found on the measured
circuit. It is also capable of measuring earth resistance and ground resistivity by the
classical voltammetric method. These measurements can be saved in the internal memory of the
voltmetric unit and downloaded onto the PC through the provided Windows software.
HT revolutionizes the portable instrument market by introducing the new JUPITER. The first
multimeter who incorporates the functions available only in standard electrical safety testers
and professional High-end multimeters.
Measuring counts:6000
AC/DC voltage: 690V / AC+DC
AC/DC current: AC+DC with external clamp transducer
M71 has been developed to measure earth resistance with 2 wires and 3 wires by voltammetric
method in compliance with standard IEC/EN61557-1.
This device allows carrying out measurements with a wide measuring range (50kΩ) and an
efficient internal automatic compensation of the disturbance effects found on the installations,
and it is provided with an ergonomic design with electronic function selector for quickly
carrying out the tests. The 2-wire method allows carrying out earth measurement by taking
advantage of appropriate external masses as a reference (metal surfaces, tubes, neutral
conductor, etc.), which is particularly useful in private environments where, because of
logistic problems, it is not possible to use the 3-wire method.
Measuring range:50KΩ
Size (LxWx H) (mm):240x100x45
Weight in grams (batteries included):600
MT-100 fully takes advantage of the touch-screen technology developed for MT-300 and, hence, of
all its settings, but its application range is for measuring earth resistance by voltammetric
method, also with optional clamp T2100 and, finally, for continuity measurement of protective
conductors. Cutting-edge management of measurement with indication, at the end of each safety
test, of compliance or non-compliance with requirements with simple symbols OK o NOT OK.
Earth resistance by voltammetric method with 2 or 3 spots in TT, TN and IT systems,
overall earth resistance measurement and with clamp meter T2100 (optional).
Ground resistivity.
Measurement of electric parameters insingle- phase installations (V,A, W, VAR, VA, PF)
Measurement of continuity of protection conduct
MT-200 fully takes advantage of the touch-screen technology developed for MT-300 and, hence, of
all its settings, but its application range is for measuring insulation resistance and earth
resistance by voltammetric method, also with optional clamp T2100 and, finally, for continuity
measurement of protective conductors. Cutting-edge management of measurement with indication, at
the end of each safety test, of compliance or non-compliance with requirements with simple
symbols OK o NOT OK.
Earth resistance by voltammetric method with 2 or 3 spots in TT, TN and IT systems,
overall earth resistance measurement and with clamp meter T2100 (optional).
Ground resistivity.
Measurement of electric parameters insingle- phase installations (V,A, W, VAR, VA, PF).
Measurement of insulation resistance.
Measurement of continuity of protection conductors with 200mA
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no
need to disconnect any part of the system (STAKELESS METHOD)
The inner part of the device is made of 2 jaws, one for current reading and the other
for voltage generation. The voltage jaws generate a potential (E) on the loop during resistance
(R) measurement. A current (I) is consequently generated on the loop and is measured by the
current jaws. Based on the value of parameters E and I, the instrument displays the resistance R
value calculated as their ratio. The value measured by the device can be used in case the single
rods do not influence each other. T2000 also measures AC current up to 20A and leakage current
with resolution 0.1mA. This device complies with standard IEC/EN61010-1 in CAT IV 300V, CAT III
600V and it is the ideal solution for measurements to be carried out both in private and in
industrial environments.
Measuring range:
Direct measurement on earth probes without any cable interruption:
Measurement of leakage current on earth systems:
Weight in grams (batteries included):
Size (LxWx H) (mm):293x105x54
T2100 is a professional clamp specially developed to evaluate resistance of earth rods with no
need to disconnect any part of the system.
The inner part of the device is made of 2 jaws, one for current reading and the other
for voltage generation. The voltage jaws generate a potential (E) on the loop during resistance
(R) measurement. A current (I) is consequently generated on the loop and is measured by the
current jaws. Based on the value of parameters E and I, the instrument displays the resistance R
value calculated as their ratio. The value measured by the device can be used in case the single
rods do not influence each other. This device complies with standard IEC/EN61010-1 in CAT III
600V, CAT IV 300V and it is the ideal solution for measurements to be carried out both in
private and in industrial environments.
COMBI521EV is the new HT instrument to perform verification and control of electric car charging
stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a
combined verification instrument, COMBI521EV also carries out tests on electric systems in
compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable,
insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A
and AC tripping time and current, line / fault impedance with calculation of prospective short
circuit / fault current, phase sequence and conformity. COMBI521EV also allows measuring and
saving environmental parameters (illuminance, temperature), leakage current and electric
quantities such as voltage, current, power factor, power and harmonics on single-phase systems.
COMBI521EV is provided with the innovative AUTO function: by selecting this function and only
setting the value of RCD current, COMBI521 carries out tests of overall earth resistance, RCD
tripping time and insulation resistance in a sequence. At the end of the test, the device shows
all results with the indication of compliance or non-compliance with the standards with simple
OK or NOT OK symbols.
The internal memory allows saving the measures and subsequently transfer them onto the
PC through the optical/USB connection. Thanks to the brand new HTAnalysis App, free to download
for iOS and Android systems, COMBI521EV is capable of transferring measured and recorded data
onto tablets and smartphones, thus giving the operator the possibility to customize and share
through HTCloud the result of their tests.
Sequence of tests for the verification of electric columns:EV-TEST100
Non-trip earth resistance:CAT IV 300V
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE: With optional accessory IMP57
oop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution
(0.1mΩ):With optional accessory IMP57
EV-TEST100 in combination with appropriate HT multifunction instrument simulates an electric
vehicle connected to the charging station, allowing you to verify the EVSE full functionality
and electrical safety. EV-TEST100 is able to test charging stations with charging modes 2 and 3
and Type 2 connector (European standard).
Test cable with connector: Type 2 (IEC 62196-2)
Input voltage: Max 415V AC, Phase-Phase, 50 / 60Hz
External load L-N-PE: 240V 50/60Hz, Max 10A AC
MACROEVTEST is the new HT instrument to perform verification and control of electric car
charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards.
Being a combined verification instrument, MACROEVTEST also carries out tests on electric systems
in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection
cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs
type B, A and AC tripping time and current, line / fault impedance with calculation of
prospective short circuit / fault current, phase sequence and conformity. MACROEVTEST also
allows measuring and saving environmental parameters (illuminance, temperature), leakage current
and electric quantities such as voltage, current, power factor, power and harmonics on
single-phase systems.
MACROEVTEST is provided with the innovative AUTO function: by selecting this function
and only setting the value of RCD current, COMBI521 carries out tests of overall earth
resistance, RCD tripping time and insulation resistance in a sequence. At the end of the test,
the device shows all results with the indication of compliance or non-compliance with the
standards with simple OK or NOT OK symbols.
The internal memory allows saving the measures and subsequently transfer them onto the
PC through the optical/USB connection. Thanks to the brand new HTAnalysis App, free to download
for iOS and Android systems, MACROEVTEST is capable of transferring measured and recorded data
onto tablets and smartphones, thus giving the operator the possibility to customize and share
through HTCloud the result of their tests.
Continuity of protective conductors with 10A
Continuity of protective conductors with 200mA
Insulation with test voltages 100, 250, 500, 1000VDC
All Rights Reserved. © 2019 Totalofftec Design By : TOTALOFFTEC